<element form="qualified" name="minimumDepthBelowLS" type="diggs:LengthMeasureType"><annotation><documentation>The minimum vertical depth below land surface for which associated construction criteria are applicable.</documentation></annotation></element>
<element form="qualified" name="maximumDepthBelowLS" type="diggs:LengthMeasureType"><annotation><documentation>The maximum vertical depth below land surface for which associated construction criteria are applicable.</documentation></annotation></element>
The method used to inject grout into the sampling feature(eg. TAM, lances, out of bottom of casing, etc.). Intended to comefrom a controlled list of terms.
<element minOccurs="0" name="injectionMethod" maxOccurs="1" type="gml:CodeType"><annotation><documentation>The method used to inject grout into the sampling feature (eg. TAM, lances, out of bottom of casing, etc.). Intended to come from a controlled list of terms.</documentation></annotation></element>
<element minOccurs="0" name="reinjectionCriteria" maxOccurs="unbounded" type="gml:CodeType"><annotation><documentation>Description of conditions whereby hole/stage may be required to be regrouted</documentation></annotation></element>
Set to true here, grouting parameters arerequired to be recorded digitally.
Diagram
Type
boolean
Properties
content
simple
minOccurs
1
fixed
true
Source
<element minOccurs="1" name="digitalRecordingRequired" type="boolean" fixed="true"><annotation><documentation>Set to true here, grouting parameters are required to be recorded digitally.</documentation></annotation></element>
<element maxOccurs="unbounded" minOccurs="0" name="recordingParameter" type="gml:CodeType"><annotation><documentation>Grouting parameter to be recorded digitally (eg. flow, pressure). Intended to come from a controlled list of terms.</documentation></annotation></element>
Set to true here, grouting parameters are NOTrequired to be recorded digitally.
Diagram
Type
boolean
Properties
content
simple
minOccurs
1
fixed
true
Source
<element minOccurs="1" name="digitalRecordingNotRequired" type="boolean" fixed="true"><annotation><documentation>Set to true here, grouting parameters are NOT required to be recorded digitally.</documentation></annotation></element>
A text string describing where the pressure sensor is located (e.g., "at pump", "at packer", "downhole at 50 ft", "surface manifold"). This is important because pressure can vary significantly between the pump and the point of injection.
A text string describing where the pressure sensor is located (e.g., "at pump", "at packer", "downhole at 50 ft", "surface manifold"). This is important because pressure can vary significantly between the pump and the point of injection.
<element minOccurs="0" name="pressureControlLogic" type="diggs:pressureControlLogicEnumType"><annotation><documentation>Property defining how grout injection is to be controlled, either by constant flow or constant pressure. From an enumerated list.</documentation></annotation></element>
<complexType name="DepthDependentGroutConstructionCriteriaType"><annotation><documentation>Extended type based on AbstractMetadataPropertyType. Adds elements for depth dependent grout construction criteria type definition.</documentation></annotation><complexContent><extension base="gml:AbstractMetadataPropertyType"><sequence><element form="qualified" name="minimumDepthBelowLS" type="diggs:LengthMeasureType"><annotation><documentation>The minimum vertical depth below land surface for which associated construction criteria are applicable.</documentation></annotation></element><element form="qualified" name="maximumDepthBelowLS" type="diggs:LengthMeasureType"><annotation><documentation>The maximum vertical depth below land surface for which associated construction criteria are applicable.</documentation></annotation></element><element maxOccurs="1" minOccurs="0" name="injectionEquipment" type="diggs:GroutInjectionEquipmentPropertyType"><annotation><documentation>Injection equipment specified.</documentation></annotation></element><element maxOccurs="1" minOccurs="0" name="mixer" type="diggs:GroutMixerPropertyType"><annotation><documentation>Mixer equipment specified</documentation></annotation></element><element maxOccurs="1" minOccurs="0" name="plant" type="diggs:GroutPlantPropertyType"><annotation><documentation>Grout plant specified</documentation></annotation></element><element maxOccurs="1" minOccurs="0" name="pump" type="diggs:GroutPumpPropertyType"><annotation><documentation>Grout pump specified</documentation></annotation></element><element minOccurs="0" name="injectionMethod" maxOccurs="1" type="gml:CodeType"><annotation><documentation>The method used to inject grout into the sampling feature (eg. TAM, lances, out of bottom of casing, etc.). Intended to come from a controlled list of terms.</documentation></annotation></element><element minOccurs="0" name="reinjectionCriteria" maxOccurs="unbounded" type="gml:CodeType"><annotation><documentation>Description of conditions whereby hole/stage may be required to be regrouted</documentation></annotation></element><choice minOccurs="0"><sequence><element minOccurs="1" name="digitalRecordingRequired" type="boolean" fixed="true"><annotation><documentation>Set to true here, grouting parameters are required to be recorded digitally.</documentation></annotation></element><element maxOccurs="unbounded" minOccurs="0" name="recordingParameter" type="gml:CodeType"><annotation><documentation>Grouting parameter to be recorded digitally (eg. flow, pressure). Intended to come from a controlled list of terms.</documentation></annotation></element></sequence><sequence><element minOccurs="1" name="digitalRecordingNotRequired" type="boolean" fixed="true"><annotation><documentation>Set to true here, grouting parameters are NOT required to be recorded digitally.</documentation></annotation></element></sequence></choice><element minOccurs="0" name="groutingPressureMaximum" type="diggs:GroutPressureMeasureType" maxOccurs="1"><annotation><documentation>Maximum grouting pressure specified.</documentation></annotation></element><element minOccurs="0" name="groutingPressureMinimum" type="diggs:GroutPressureMeasureType" maxOccurs="1"><annotation><documentation>Minimum grouting pressure specified.</documentation></annotation></element><element minOccurs="0" name="groutVolumeMaximum" type="diggs:VolumeMeasureType"><annotation><documentation>Maximum grout volume specified.</documentation></annotation></element><element minOccurs="0" name="groutVolumeMinimum" type="diggs:VolumeMeasureType"><annotation><documentation>Minimum grout volume specified</documentation></annotation></element><element minOccurs="0" name="InjectionRateMaximum" type="diggs:VolumePerTimeMeasureType"><annotation><documentation>Maximum specified rate of grout injection</documentation></annotation></element><element minOccurs="0" name="injectionRateMinimum" type="diggs:VolumePerTimeMeasureType"><annotation><documentation>Minimum specified rate of grout injection</documentation></annotation></element><element minOccurs="0" name="pressureControlLogic" type="diggs:pressureControlLogicEnumType"><annotation><documentation>Property defining how grout injection is to be controlled, either by constant flow or constant pressure. From an enumerated list.</documentation></annotation></element><element minOccurs="0" name="stageLengthMaximum" type="diggs:LengthMeasureType"><annotation><documentation>Maximum specified stage length.</documentation></annotation></element><element minOccurs="0" name="stageLengthMinimum" type="diggs:LengthMeasureType"><annotation><documentation>Minimum specified stage length.</documentation></annotation></element></sequence></extension></complexContent></complexType>